# Insulation Calculator

Enter the size of the attic or floor, pick your climate zone and the insulation you plan to use. You get the R-value to aim for, the depth that gives it, and for blown-in fiberglass the number of bags.

Reviewed by FigureYard editorial team · Updated October 14, 2026 · 4 sources

*Interactive calculator on the page (inputs: Length; Width; Where; Climate zone; Insulation). The results below are for its default inputs.*

**Recommended R-value**

**R-60**

- Settled depth for R-60: **20.5** in
- Area: **1,200** sq ft
- Volume of insulation: **2,050** cubic feet

Buy

- **38** bags for R-60

R-value measures how well insulation resists heat. ENERGY STAR publishes the levels that pay off in each climate zone, from the warm South to the far North, and each material reaches them at a different depth: loose fiberglass needs the most, closed-cell spray foam the least.

## How to use this calculator

1. Measure the attic floor or the floor over the crawl space, length and width.
2. Pick where the insulation goes. If the attic already has a few inches, choose that option: the target is then the amount to add.
3. Pick your climate zone. The Department of Energy's climate zone map shows it by county.
4. Choose the insulation. For blown-in fiberglass you also get a bag count from one maker's coverage chart.

## Worked examples

### An empty attic in a cold climate

Size: 40 × 30 ft · Where: Attic floor, no insulation now · Climate zone: Zone 7 or 8

- Recommended R-value: R-60
- Bags for R-60: 38
- Settled depth for R-60: 20.5 in
- Area: 1,200 sq ft
- Volume of insulation: 2,050 cubic feet

### Topping up an attic

Size: 50 × 28 ft · Where: Attic floor, 3 to 4 in already there · Climate zone: Zone 4A or 4B

- R-value to add: R-49
- Bags for R-49: 35
- Settled depth for R-49: 17.0 in
- Area: 1,400 sq ft
- Volume of insulation: 1,983 cubic feet

### Cellulose in a mild climate

Size: 36 × 26 ft · Where: Attic floor, no insulation now · Climate zone: Zone 3 · Insulation: Blown-in cellulose

- Recommended R-value: R-49
- Depth for that R-value: 13.2 in
- Area: 936 sq ft
- Volume of insulation: 1,033 cubic feet

### Floor over a crawl space

Size: 40 × 25 ft · Where: Floor over a crawl space or garage · Climate zone: Zone 4C, 5 or 6 · Insulation: Fiberglass batts or rolls

- Recommended R-value: R-30
- Depth for that R-value: 9.4 in
- Area: 1,000 sq ft
- Volume of insulation: 781 cubic feet

## Recommended R-values by climate zone

ENERGY STAR's table, based on the model energy code, asks for R-30 in an uninsulated attic in the warmest zone and R-60 in the colder zones. If the attic already has a few inches of insulation, add R-25 to R-49 on top.

Floors over unheated space get less: from R-13 in the South to R-38 in the coldest zones.

## R-value per inch of common insulation

- Blown fiberglass: about R-2.2 per inch, so it takes the most depth.
- Fiberglass batts: about R-3.2 per inch.
- Blown cellulose: about R-3.7 per inch.
- Open-cell spray foam: about R-3.6 per inch.
- Closed-cell spray foam: about R-6.1 per inch, the most per inch of these.

## Before you add insulation

- Seal the gaps around pipes, wires, chimneys and the attic hatch first: air leaks carry more heat than thin insulation does.
- Keep soffit vents open with baffles so the attic can still breathe.
- Keep insulation the required distance from recessed lights unless they are rated for contact, and from chimneys and flues.

## Common questions

### How much insulation do I need in my attic?

It depends on your climate zone. ENERGY STAR recommends R-30 in the warmest zone and R-60 in most of the country's colder zones. Pick your zone above to see the depth for your insulation.

### How many bags of blown-in insulation do I need?

Divide the attic area by a thousand and multiply by the bag count on the coverage chart for your R-value. For R-38, one maker's chart calls for 19 bags per 1,000 sq ft; the calculator does the math for your attic.

### How deep should blown-in insulation be?

Deep enough to reach the R-value on the bag chart. For one maker's blown fiberglass, R-49 takes about 17 inches settled. Cellulose reaches the same R-value with less depth.

### Can I put new insulation over old insulation?

Yes, as long as the old insulation is dry and has no mold. Lay new batts across the old ones without a facing, or blow loose fill on top.

## Related calculators

- [Attic Ventilation Calculator](https://figureyard.com/roofing/attic-ventilation-calculator/)
- [BTU Calculator for Room Air Conditioners](https://figureyard.com/energy/btu-calculator/)
- [Square Footage Calculator](https://figureyard.com/measure/square-footage-calculator/)

Reviewed by FigureYard editorial team on 2026-10-09. Formulas are tested against published values, and material figures come from the sources below. [How we build our calculators](https://figureyard.com/editorial-policy/).

## Sources

- [University of Maryland Extension: Home Energy: Insulation](https://extension.umd.edu/resource/home-energy-insulation)
- [US DOE Building America / EERE: Which Spray Foam Is Right For You? (Building America)](https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/spray_foam_guide.pdf)
- [ENERGY STAR: Recommended Home Insulation R-Values (based on the 2021 IECC, Table R402.1.3)](https://www.energystar.gov/saveathome/seal_insulate/identify-problems-you-want-fix/diy-checks-inspections/insulation-r-values)
- [Owens Corning: AttiCat Expanding Blown-In PINK FIBERGLAS Insulation, coverage chart (Pub. No. 10009393-E, November 2022)](https://www.owenscorning.com/dms/10009393)