# Water Heater Size Calculator

Choose a tank or a tankless heater. For a tank, count the hot water uses in your busiest hour; for a tankless heater, count what runs at once and pick the temperature of your incoming water. You get the rating to shop for.

Reviewed by FigureYard editorial team · Updated October 12, 2026 · 4 sources

*Interactive calculator on the page (inputs: Water heater; Showers in the busiest hour; Baths in the busiest hour; Shaves in the busiest hour; Hand and face washes in the busiest hour; Shampoos in the busiest hour; Hand dishwashing in the busiest hour; Dishwasher loads in the busiest hour; Food preparation in the busiest hour; Laundry loads (warm or hot) in the busiest hour; Showers running; Sinks running; Dishwasher; Clothes washer; Incoming water temperature). The results below are for its default inputs.*

**First-hour rating**

**41** gallons

- Look for a rating of: **41 to 43 gallons**

Tank size alone is a poor guide. The Department of Energy sizes a storage heater by its first-hour rating, the hot water it delivers in an hour starting full, and a tankless heater by the flow it can heat through the temperature rise you need.

## How to use this calculator

1. Choose tank or tankless.
2. Tank: think of your busiest hour, often a weekday morning, and enter how many showers, shaves, dishwasher loads and so on happen in it.
3. Tankless: enter how many showers, sinks and appliances may run at the same time, and the temperature of your incoming water.
4. Shop by the first-hour rating on the EnergyGuide label, or by the flow a tankless heater gives at your temperature rise.

## Worked examples

### A couple's morning

Water heater: Tank (storage) · Showers in the busiest hour: 2 · Shaves in the busiest hour: 1 · Hand and face washes in the busiest hour: 1 · Food preparation in the busiest hour: 1

- First-hour rating: 39 gallons
- Look for a rating of: 39 to 41 gallons

### A family's busy hour

Water heater: Tank (storage) · Showers in the busiest hour: 3 · Shaves in the busiest hour: 1 · Hand and face washes in the busiest hour: 2 · Dishwasher loads in the busiest hour: 1 · Food preparation in the busiest hour: 1

- First-hour rating: 70 gallons
- Look for a rating of: 70 to 72 gallons

### Tankless, two showers at once

Water heater: Tankless (on demand) · Showers running: 2 · Sinks running: 1 · Incoming water temperature: 50 °F

- Tankless heater: 7.2 gallons per minute
- Temperature rise: 70 °F

### Tankless in a cold-water region

Water heater: Tankless (on demand) · Showers running: 1 · Sinks running: 1 · Dishwasher: 1 · Incoming water temperature: 40 °F

- Tankless heater: 6.0 gallons per minute
- Temperature rise: 80 °F

## Sizing a tank water heater

DOE's method adds up the hot water used in your busiest hour and looks for a heater whose first-hour rating comes within about 2 gallons of it. Its estimates per use are a shower 15 gallons, a bath 20 gallons, a shave 2 gallons, a shampoo 4 gallons, food preparation 5 gallons, an automatic dishwasher 14 gallons and a warm or hot laundry load 32 gallons.

Those figures are from an older DOE fact sheet; today's efficient dishwashers and washers use less hot water, so your peak may come in lower.

## Sizing a tankless water heater

A tankless heater must heat everything that runs at once. ENERGY STAR's sizing figures are 2.5 gallons per minute for a shower, 2.2 gallons per minute for a sink, 1.3 gallons per minute for a dishwasher and 3.3 gallons per minute for a clothes washer. Add up the flows, then find the rise: the outlet temperature, usually 120 °F, less the coldest your incoming water gets.

As a rough guide, DOE puts a gas tankless unit at about 5 gallons per minute and an electric one at about 2 gallons per minute at a seventy-degree rise. Cold incoming water in winter cuts the flow a unit can deliver.

## The right temperature

Set the heater to 120 °F: it saves energy and lowers the risk of scalds. The CPSC notes that a serious burn takes about 5 minutes at 120 °F, but only 6 seconds at 140 °F and 2 seconds at 150 °F.

## Common questions

### What size water heater do I need?

One whose first-hour rating matches the hot water you use in your busiest hour, by DOE's method. The calculator adds it up from the showers, shaves and loads in that hour.

### What size water heater for a family of four?

It depends on the busiest hour more than the head count. For one sample morning, three showers, a shave, two hand and face washes, a dishwasher load and some food preparation in the same hour, look for a first-hour rating of about 70 gallons. Enter your own family's morning to check yours.

### How do I size a tankless water heater?

Add up the flow of everything that runs at once and find the temperature rise from your incoming water to 120 °F. Buy a unit rated for that flow at that rise.

### What temperature should a water heater be set to?

120 °F, as the Department of Energy and the CPSC recommend, to save energy and prevent scalds.

## Related calculators

- [Water Usage Calculator](https://figureyard.com/pool/water-usage-calculator/)
- [Electricity Cost Calculator](https://figureyard.com/energy/electricity-cost-calculator/)
- [BTU Calculator for Room Air Conditioners](https://figureyard.com/energy/btu-calculator/)

Reviewed by FigureYard editorial team on 2026-10-09. Formulas are tested against published values, and material figures come from the sources below. [How we build our calculators](https://figureyard.com/editorial-policy/).

## Sources

- [U.S. Department of Energy, Office of Building Technology, State and Community Programs (with NREL): Water Heating: Energy-efficient strategies for supplying hot water in the home (BTS Technology Fact Sheet, DOE/GO-102001-0785)](https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/26465.pdf)
- [U.S. Department of Energy Building America program / NREL (IBACOS): Measure Guideline: Transitioning to a Tankless Water Heater (DOE/GO-102012-3568)](https://www1.eere.energy.gov/buildings/publications/pdfs/building_america/measure_guide_tanklesswh.pdf)
- [ENERGY STAR (U.S. EPA and U.S. DOE): Whole Home Tankless Gas Water Heaters | ENERGY STAR](https://www.energystar.gov/products/whole_home_tankless_gas_water_heaters)
- [U.S. Consumer Product Safety Commission (CPSC): Publication 5098 - Avoiding Tap Water Scalds](https://www.cpsc.gov/s3fs-public/5098.pdf)