Wire Size for a 200 Amp Service

A 200 amp service for a single-family house takes 2/0 AWG copper or 4/0 AWG aluminum. These sizes come from the code's dwelling table, which lets the conductors that carry a whole home's load be sized for 83 percent of the rating. 4/0 aluminum is by far the most common choice, usually as SE cable from the meter to the panel or as USE cable underground.

Reviewed by FigureYard editorial teamUpdated October 13, 20267 sources

Your measurements

Remembered on this device
A
V
Conductor
More options
%
Wire size
4/0 AWGaluminum
  • Current the service wire must carry: 166.0 A
  • Rated for: 180 A
  • Voltage drop: 0.67%
  • Longest run within 3%: 180 ft
Each aluminum size for this circuit
SizeRatedDropFits
4 AWG65 A3.39%Too small for the current
3 AWG75 A2.69%Too small for the current
2 AWG90 A2.13%Too small for the current
1 AWG100 A1.69%Too small for the current
1/0 AWG120 A1.34%Too small for the current
2/0 AWG135 A1.06%Too small for the current
3/0 AWG155 A0.84%Too small for the current
4/0 AWG180 A0.67%Yes

4/0 AWG aluminum service conductor (83% of the rating, 75 °C column) is the smallest size here; the service rating sets it. A service that feeds a whole single-family house may be sized for 83% of its rating (NEC 310.12); a feeder to a subpanel or a detached building is not, so choose a circuit or a subpanel for that. This uses the base table: hot attics, more than three current-carrying wires together, and the terminals on your breaker and devices can call for a larger size. Have an electrician or your inspector confirm the circuit.

The calculator is preset to a 200 amp whole-house service in aluminum. Enter the distance from the meter to the main panel to see whether a long run calls for more than the table size.

How to use this calculator

  1. Keep the rating at 200 amps, the main breaker.
  2. Choose aluminum for the usual SE or USE cable, or copper for an older or a commercial-style installation.
  3. Enter the one-way distance from the meter base or the service disconnect to the panel.
  4. Feeding a 200 amp subpanel or a second building instead? Switch to a circuit or a subpanel; that feeder carries the full rating and takes larger wire.

Worked examples

A panel on the other side of the meter wall

The wire feeds: A whole house (service) · Load current: 200 A · Circuit voltage: 240 V · One-way distance: 10 ft · Conductor: Aluminum

Wire size
4/0 AWG aluminum
Current the service wire must carry
166.0 A
Rated for
180 A
Voltage drop
0.17%
Longest run within 3%
180 ft

An underground service from a pedestal

The wire feeds: A whole house (service) · Load current: 200 A · Circuit voltage: 240 V · One-way distance: 90 ft · Conductor: Aluminum

Wire size
4/0 AWG aluminum
Current the service wire must carry
166.0 A
Rated for
180 A
Voltage drop
1.50%
Longest run within 3%
180 ft

A copper service entrance

The wire feeds: A whole house (service) · Load current: 200 A · Circuit voltage: 240 V · One-way distance: 25 ft

Wire size
4/0 AWG aluminum
Current the service wire must carry
166.0 A
Rated for
180 A
Voltage drop
0.42%
Longest run within 3%
180 ft

Service conductor size for a 200 amp dwelling by distance

One-way distanceCopperAluminum
10 ft2/0 AWG4/0 AWG
25 ft2/0 AWG4/0 AWG
50 ft2/0 AWG4/0 AWG
75 ft2/0 AWG4/0 AWG

Each cell: the smallest conductor under the dwelling service rule that keeps the drop at full rated current within the branch-circuit limit. A longer run can go past the largest size this calculator lists; size it with an electrician.

Where 2/0 copper and 4/0 aluminum come from

The rule asks the conductors to carry 83 percent of the service rating. 2/0 AWG copper is rated 175 amps and 4/0 AWG aluminum 180 amps in the higher temperature column, and both clear that share of a 200 amps service. The calculator applies the same rule, so its answer for this rating matches the table row.

A 200 amp subpanel is a different answer

The allowance belongs only to the conductors that carry the whole load of one dwelling. A 200 amp feeder to a subpanel, a garage or a second house must carry the full rating from the regular table: 3/0 AWG copper is rated 200 amps, and aluminum goes beyond the largest size listed here. For a smaller feed see the 100 amp subpanel page.

Who installs the service

The service entrance belongs partly to the utility: they set the meter, often specify the meter base and the underground conductors, and will not energize a new service until the inspector signs it off. Plan the upgrade with them and a licensed electrician; the calculator is for knowing what to expect on the quote, and the 100 amp service page shows the smaller version.

Common questions

What size wire for a 200 amp service?

2/0 AWG copper or 4/0 AWG aluminum for the service of a single-family house, under NEC Table 310.12.

Is 4/0 aluminum good for 200 amps?

For a whole-house service, yes: it is rated 180 amps, more than the share of the rating the dwelling rule requires. For a 200 amp subpanel feeder it is too small.

Is 2/0 copper good for 200 amp service?

Yes, for a single-family service: 2/0 copper is rated 175 amps in the higher temperature column, and the rule asks for 83 percent of the rating.

What size wire for a 200 amp subpanel?

Larger than the service: a feeder to a subpanel carries the full rating, so 3/0 AWG copper, rated 200 amps, or a larger aluminum conductor.